Placeholder image
germany Deutsch
england Englisch


Technical data

ReguCellTouch

Product:
  RCT
Product type:
  Microcurrent device
Product form:
  Tabletop device
Material type:
  ABS plastic housing
Protection class housing:
  IP20
Protection type light handpieces:
  IP54
Photon therapy:
  interferent
Structure-borne sound therapy:
  interferent
CE marking:
  0044
MPG classification:
  Class IIa medical device with type BF applied part
UMDNS classification:
  Electrotherapy device (11-503)
Dimensions:
  W x D x H: 325 x 232 x 128 (mm)
Weight:
  1.89 kg (without accessories)
Ambient temperature operation:
  +5°C - +40°C
Relative humidity operation:
  15 - 93% (non-condensing)
Air pressure operation:
  700 – 1060 hPa
Outputs patient:
  4 + 2
Output current patient:
  10µA – 999µA in 1µA steps
Output voltage patient (max):
  60V   
Patient output frequency:
 
0.1Hz – 10kHz in 0.1Hz steps
Diagnostics:
  Logarithmic resistance measurement



ReguCell TravelHome

Product/Product Type:
MSTU 100-MC-00 / microcurrent device
Product form:
  Tabletop device
Material type:
  Aluminum housing with glass front
Protection class housing / light handpiece:
  IP00 / IP20
CE marking:
  0044
MPG classification:
  Class IIa medical device with type BF applied part
UMDNS classification:
  Electrotherapy device (11-503)
Dimensions (W x D x H):
  173.0 x 108.8 x 27.6 (mm)
Weight:
  590 g (without accessories)
Power supply:
  ATM0361-A050
Power consumption max.:
  25W
Battery:
  Li-ion 3.8V/3880mAh 14.7Wh type RRC1130
Transport/Storage:
  -10°C - +50°C at humidity up to 93% (non-condensing)
Ambient temperature operation:
  +5°C - +40°C
Relative humidity operation:
  15 - 93% (non-condensing)   
Air pressure operation:
 
700 – 1060 hPa
Outputs patient:
  2 x microcurrent + 1 x sound
10µA – 999µA in 1µA steps
60V
0.4Hz – 1kHz in 0.1Hz steps
1 x 0 – 300mA in 3.0 mA steps
5V
0.4Hz – 1kHz in 0.1Hz steps
2.1W
0.39W/cm2
Logarithmic resistance measurement (+/- 20% of Ω value)
Rx Sensitivity: -93 dBm @ 1%, Tx Power (max.): 0 dBm

Placeholder image
Placeholder image
Placeholder image
Placeholder image
Placeholder image
Placeholder image

Important NOTE: The modes of action and medical applications described below for the devices from “ReguCell Products” come from complementary medicine and are intended as an alternative and supplement to scientifically based treatment methods in conventional medicine. The statements are currently only based on studies of small cohort groups, pilot studies, application observations and/or experience reports. In particular, there are no studies of evidence level Ib (methodologically high-quality randomized placebo-controlled studies with a sufficient number of test subjects) or even level Ia (meta-analysis based on several methodologically high-quality level Ib studies), so that the therapy, methodology and the options for action described have not yet been sufficiently proven by conventional medical science and are therefore considered controversial.